Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Application Case
Home ProductsOutdoor Battery Cabinet

Mini size Outdoor Battery Cabinet Solar System and Telecom Base Station

Good quality High Frequency Online UPS for sales
Good quality High Frequency Online UPS for sales
As an exclusive agent UPS distributor of SORO, We enjoyed wonderful business cooperation with them. Let's grow fast together!

—— Dennis Spalding --from LAX, USA

Perfect UPS, Perfect software(SNMP card), Perfect service, that is SORO UPS!!!

—— Antonie Williams --from Dubai

April, 2015, I visited Sorotec factories, I was pleasantly suprised by their design and artwork to ensure quality!!

—— Anuoluwapo Omobolaji Ayokunle

I'm Online Chat Now

Mini size Outdoor Battery Cabinet Solar System and Telecom Base Station

China Mini size Outdoor Battery Cabinet Solar System and Telecom Base Station supplier
Mini size Outdoor Battery Cabinet Solar System and Telecom Base Station supplier Mini size Outdoor Battery Cabinet Solar System and Telecom Base Station supplier

Large Image :  Mini size Outdoor Battery Cabinet Solar System and Telecom Base Station

Product Details:

Place of Origin: China
Brand Name: SOROTEC
Certification: CE
Model Number: Outdoor Battery Cabinet

Payment & Shipping Terms:

Minimum Order Quantity: 10PCS
Packaging Details: Standard Exported Cartons and Pallets
Delivery Time: Within 15-30days after receiving your 30% TT deposit
Payment Terms: L/C, T/T
Supply Ability: 3000PCS Per Month
Contact Now
Detailed Product Description

 

Mini size Outdoor Battery Cabinet Solar System and Telecom Base Station

 

Footprint and Energy Saving

1.Mi-ni-size decreasing 60% footprint, easing site acquisition preassure and decreasing development cost.

2.In non-high-temperature areas, using independent temperature control method without A/C, reducing 50-80% cooling popwer consumption.

3.In high-temperature areas, adopting intelligent heat exchanger system, decreasing A/C running time, saving energy 40-60%.

4.Independent cooling for battery, prolonging its lifespam 2-5 years.

 

Product Show:

Mini size Outdoor Battery Cabinet Solar System and Telecom Base Station

 

Mini size Outdoor Battery Cabinet Solar System and Telecom Base Station

 

All-in-one, Orderliness

1.Large housing capability, minizing the number of outdoor cabinet.

2.All-in-one.Main equipment, temperature control equipment, popwer system, battery, ACDC, DCDU.

3.Simplifying the site design, making the site orderly.

 

Fast Deployment, ROI Improvement

1.Supporting installation in the factory and transportation as a whole.

2.Supporting shipment in components and onsite assembly.

3.Onsite assembly for a three-unit-combination takes about 2 hours by 4 persons.

4.Less civil engineering.

 

 

TRADE SHOW

 

T49.jpg

 

 

FAQ

 

1. How to choose suitable inverter?

 

If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.

 

For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.

 

Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power

.......................................................................................................................................................................

 

2. How do I choose the size of the inverter?

 

Different types of load demand for power are different. You can view the load power values to determine the

size of the power inverter.

 

Notice:

 

Resistive load: you can choose the same power as the load.

 

Capacitive loads: according to the load, you can choose 2-5 times power.

 

Inductive loads: according to the load, you can choose 4-7 times power.

.......................................................................................................................................................................

3. How connection between batteries and an power inverter?

 

We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions

.......................................................................................................................................................................

 

4. How to calculate the load of working hours requires configuration of the battery size?

 

We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:

Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)

.......................................................................................................................................................................