3 Phase 20KVA / 14KW, 15KVA /10.5KW True online double conversion High Frequency UPS
Contact Person : Ella
Phone Number : 0755-81495850
WhatsApp : +8613682556888
| Minimum Order Quantity : | 1pcs | Price : | 1000USD |
|---|---|---|---|
| Packaging Details : | Standard Exported Cartons and Pallets | Delivery Time : | Within 15-30days after receiving your 30% TT deposit |
| Payment Terms : | L/C, T/T, Western Union | Supply Ability : | 5000PCS Per Month |
| Place of Origin: | China | Brand Name: | SOROTEC /OEM |
|---|---|---|---|
| Certification: | CE,ROHS,RSO9000 | Model Number: | HP9335C PLUS 10-30KVA |
|
Detail Information |
|||
| Product Name: | Uninterruptible Power Supply | Type: | Online UPS |
|---|---|---|---|
| Phase: | Three Phase | Application: | Telecom |
| Output Power Factor: | 0.9 | Waveform: | Pure Sine Wave |
| Frequency: | 50/60HZ | Nominal Voltage: | 380/450/415vac |
| Communications: | SNMP+USB+RS232 | Dual Mains Input: | Support |
| Parallel Mode: | N+X | Stable And Safety: | With Isolation Transformer |
| Ebergy Saving UPS: | Yes | Emergency Power Off: | Support |
| Maintenance Bypass: | Available | ||
| Highlight: | pure sine wave ups,high frequency ups |
||
Product Description
1800W high frequency ups uninterruptible power supplies with Isolation Transformer
Quick Detailes:
Model :High Frequency Online UPS
Capacity:10Kva-30Kva
Phase:3 Ph in/3Ph out
Output Power Factor: 0.9
Online AC-DC-AC Transfer
Safety Output with Isolation Transformer
Standard Model/Long-Run Model Have
Key Features:
1. Output power factor 0.9
2. Accepts dual-mains inputs
3. Generator compatible
4. True double-conversion
5. Compact Design, Lower Noise
6. Maintenance bypass available
7. Optional N+X parallel redundancy
8. N+X Parallel Redundancy Optional
9. Emergency power off function (EPO)
10. 50Hz/60Hz frequency converter mode
11. ECO mode operation for energy saving
12. Wide input voltage range (110-300 VAC)
13. Active power factor correction in all phases
14. Full DSP control of high stability, reliability and safety.
15. Humanistic LCD panel information.RS232 communication interface
16. 3-stage extendable charging design for optimized battery performance
17. Optional isolation transformer offers full isolation and complete common mode noise rejection
![]()
Technical Parameters :
| MODEL | HP9335C Plus 10-30KVA | ||||||||
| 10K | 10K-XL | 15K | 15K-XL | 20K | 20K-XL | 30K | 30K-XL | ||
| CAPACITY | 10KVA / 9KW | 15KVA / 13.5KW | 20KVA / 18KW | 30KVA / 27KW | |||||
| PHASE | 3 Phase with Neutral | ||||||||
| INPUT | |||||||||
| Voltage Range | Low Line Loss | 110 VAC(Ph-N) ± 3 % at 50% Load ; 176 VAC(Ph-N) ± 3 % at 100% Load | |||||||
| Low Line Comeback | Low Line Loss Voltage + 10V | ||||||||
| High Line Loss | 300 VAC(Ph-N) ± 3 % | ||||||||
| High Line Comeback | High Line Loss Voltage - 10V | ||||||||
| Phase | Three phase with ground | ||||||||
| Power Factor | ≥ 0.99 at 100% Load | ||||||||
| OUTPUT | |||||||||
| Output voltage | 208/220/230/240VAC(Ph-N) | ||||||||
| AC Voltage Regulation | ± 1% | ||||||||
| Frequency Range (Synchronized Range) | 46Hz ~ 54 Hz @ 50Hz system ; 56Hz ~ 64 Hz @ 60Hz system | ||||||||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | ||||||||
| Overload | AC mode | 100%~110%: 10min ; 110%~130%: 1min ; >130% : 1sec | |||||||
| Battery mode | 100%~110%: 30sec ; 110%~130%: 10sec ; >130% : 1sec | ||||||||
| Current Crest Ratio | 3:1 max | ||||||||
| Harmonic Distortion | ≦ 2 % @ 100% Linear Load; ≦ 5 % @ 100% Non-linear Load | ||||||||
| Transfer Time | Line←→Battery | 0 ms | |||||||
| Inverte←→Bypass | 0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass) | ||||||||
| Line←→ECO | <10 ms | ||||||||
| EFFICIENCY | |||||||||
| AC mode | > 89% | > 89% | > 89% | > 90% | |||||
| Battery Mode | > 86% | > 88% | > 87% | > 89% | |||||
| BATTERY | |||||||||
| Standard Model | Type |
12 V / 9 Ah | 12 V / 9 Ah | 12 V / 9 Ah | 12 V / 9 Ah | ||||
| Numbers | 20(18-20 adjustable) | 2 x 20(18-20 adjustable) | 2 x 20(18-20 adjustable) | 3 x 20(18-20 adjustable) | |||||
| Recharge Time | 9 hours recover to 90% capacity | ||||||||
| Charging Current | 1.0 A ± 10% (max.) | 2.0 A ± 10% (max.) | 2.0 A ± 10% (max.) | 4.0 A ± 10% (max.) | |||||
| Charging Voltage | 273 VDC ± 1% | ||||||||
| Long-run Model | Type | Depending on applications | |||||||
| Numbers | 18-20 | ||||||||
| Charging Current | 4.0 A ± 10% (max.) | 4.0 A ± 10% (max.) | 4.0 A ± 10% (max.) | 12.0 A ± 10% (max.) | |||||
| Charging Voltage | 273 VDC ± 1% | ||||||||
| PHYSICAL | |||||||||
| Standard Model | Dimension,DxWxH(mm) | 832 X250X894 | 832 X250X1275 | ||||||
| Long-run Model | Dimension,DxWxH(mm) | 609 X250X768 | 832 X250X828 | ||||||
| ENVIRONMENT | |||||||||
| Operation Temperature | 0 ~ 40°C (the battery life will down when > 25°C) | ||||||||
| Operation Humidity | <95 % and non-condensing | ||||||||
| Operation Altitude | <1000m | ||||||||
| Acoustic Noise Level | Less than 58dB @ 1 Meter | Less than 60dB @ 1 Meter | |||||||
| MANAGEMENT | |||||||||
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC | ||||||||
| USB | Power management from SNMP manager and web browser | ||||||||