Single phase 220V 90KW / 100KW / 200KW EPS Emergency Power Supply with CPU control
Contact Person : Ella
Phone Number : 0755-81495850
WhatsApp : +8613682556888
Minimum Order Quantity : | USD10000 | Packaging Details : | Standard Exported Cartons and Pallets |
---|---|---|---|
Delivery Time : | Within 15-30days after receiving your 30% TT deposit | Payment Terms : | 30% TT in advance, the balance before shipping |
Supply Ability : | 10000PCS/Month for Inverter and line Interactive UPS; Advance 3000PCS/Month for Online UPS |
Place of Origin: | China | Brand Name: | SOROTEC |
---|---|---|---|
Certification: | CE,ROHS,ISO9000 |
Detail Information |
|||
High Light: | uninterruptable power supplies,uninteruptible power supply |
---|
Product Description
AC - DC VRLA non continuous EPS Emergency Power Supply with LCD display for under voltage
Key Features
Our lighting EPS is equipped with power auto-transformation unit, so both AC and DC power supply can be used in it.
Protection devices for over voltage, under voltage, overheat, over current, short-circuit and more are available in our lighting EPS.
It can be used in combination with fire linkage.
RS232 or RS485 remote monitoring.
Designed with CPU control and LCD display.
Smart charge management system.
Long service life..
Applications
Fire proofElevator, sprays pump and automatic door, etc.High risk buildingElevator, water pump, fans, etc.Financial system equipmentBig screen of stock exchange, security monitor system, financial machine tools, national treasury.Other applicationsThe military radar, vehicle mobile phone, civil air defense channel, underground facility, hospital and operating room, school, public square, station, park, sport place, meeting and exhibition center.
Technical Specification of Lighting EPS YJ series
model | YJ series 0.5-10KW | ||||||||||||||
0.5KW | 1KW | 1.5KW | 2KW | 3KW | 4KW |
5 KW |
6 KW |
7 KW |
8 KW |
9 KW |
10 KW |
||||
Input | |||||||||||||||
Voltage | Single phase 220VAC±20% | ||||||||||||||
Frequency | 50HZ±10% | ||||||||||||||
Output | |||||||||||||||
Voltage |
Synchronized with the utility (AC mode), 220VAC ± 3%(battery mode) |
||||||||||||||
Frequency |
Synchronized with the utility (AC mode), 50HZ ± 0.5%(battery mode) |
||||||||||||||
Wave form | Sine wave (THD ≤ 3%) | ||||||||||||||
Battery | |||||||||||||||
Type |
VRLA (valve regulated lead acid), sealed, and maintain-free. |
||||||||||||||
Nominal voltage | 36VDC | 96VDC | |||||||||||||
Charge time | < 24 hours | ||||||||||||||
Transfer time | <5 s ≤ 0.25s, ≤ 0.25ms or 0ms is optional) | ||||||||||||||
Backup time |
90 minutes (Chinese standard, and it's adjustable.) |
||||||||||||||
Protection |
Overload, short-circuit, low voltage and lacking phase. |
||||||||||||||
Display | LED or LCD, or both LED and LCD | ||||||||||||||
Efficiency | DC mode ≥ 92%, AC mode ≥ 98% | ||||||||||||||
Working condition | |||||||||||||||
Noisy (1 m distance) |
AC mode 0 dB, DC mode ≤50dB (≥75KW, ≤65dB) | ||||||||||||||
Humidity | 0-90% non condensing | ||||||||||||||
Temperature | -20℃ - 40℃ | ||||||||||||||
Height of sea level |
> 2000m | ||||||||||||||
Adaptive load |
Suitable to both the inductive load and inductance capacitance load, or mixed load. |
||||||||||||||
Output circuit (standard) |
3 (continuous style, non-continuous style or automatic control style) |
||||||||||||||
Physical Characteristic |
|||||||||||||||
Weight(KG) | 60 | 80 | 560 | 650 | 750 | 850 | |||||||||
Size (mm) (W×D×H) |
600×215 ×600 |
600×215×1100 | 8000×600×2200 |
Enter Your Message