Modified sine wave 240VAC UPS Power Inverter IG3110E Series 600VA, 900VA, 1400VA, 1800VA
Contact Person : Ella
Phone Number : 0755-81495850
WhatsApp : +8613682556888
Minimum Order Quantity : | 2 pieces | Packaging Details : | Standard Exported Cartons and Pallets |
---|---|---|---|
Delivery Time : | Within 15-30days after receiving your 30% TT deposit | Payment Terms : | 30% TT in advance, the balance before shipping |
Supply Ability : | 10000PCS/Month for Inverter and line Interactive UPS; Advance 3000PCS/Month for Online UPS |
Place of Origin: | China | Brand Name: | SOROTEC |
---|---|---|---|
Certification: | CE,ROHS,ISO9000,ISO14000 | Model Number: | IG3117C 3000 - 5000VA |
Detail Information |
|||
Phase: | Single Phase | Weight: | 5 - 13.5kg |
---|---|---|---|
Output Voltage: | 200/220/230/240V | Color: | Black |
Wave Form: | Pure Sine Wave | Norminal Output Voltage: | 110/120VAC, 220/230/240VAC |
Output Frequency: | 50/60Hz ± 0.1% | Operating Temperature: | - 10 ~50℃ |
Storage Temperature: | - 40 ~85 ℃ ℃ | ||
High Light: | solar energy inverter,home power inverter |
Product Description
3000va pure sine wave inverter dc-ac power inverter for home
1. Two times of rating power.
2. Intelligent cooling fan speed control determined by loads and pure sine wave output available for sensitive loads.
3. With advanced MCU microprocessor control technology the built-in AC charger will charge batteries automatically and high efficient DC-AC conversion minimizing energy loss.
4. High-frequency switching technology for compact size and light weight.
5. High power density design.
6. Multiple protection: Input low voltage / Overload / Short circuit / Low battery alarm / Input over voltage / over temperature.
7. LCD digital display will show voltage, frequency, battery and load information.
PRODUCT SHOW |
Product Descriptions of Power Inverter Dc 12V Ac 220V
MODEL | IG3117C 3000VA-5000VA | ||||||||
Capacity | 3000VA/2400W | 5000VA/4000W | |||||||
Nominal Voltage | 230VAC | ||||||||
Nominal Frequency | 50HZ/60Hz | ||||||||
Input | |||||||||
Voltage Range | 170VAC ~270VAC(Normal range) | ||||||||
91~284VAC(generator/wide range) | |||||||||
Frequency range | 40HZ±1Hz ~65Hz±1Hz | ||||||||
Output | |||||||||
Voltage Regulation | 230VAC±10% | ||||||||
Frequency Regulation | 50HZ/60Hz±1Hz(Auto detection) | ||||||||
Wave Form | Pure sine wave | ||||||||
Power Factor | 0.8 | ||||||||
Efficiency | ≥90%(battery mode) | ||||||||
≥98%(line mode) | |||||||||
Over-load Protection | At 110%-150% Load For 10s | ||||||||
Load >150% For 5s | |||||||||
Surge Rating | 10000VA | ||||||||
Transfer time | 10ms | ||||||||
Battery | |||||||||
DC voltage | 24Vor48vdc | 48Vor96vdc | |||||||
Nominal charge current | 20A(95-175V,gen/wide,only) | ||||||||
20/35A(Optional) | |||||||||
Overcharge protection | Bat. V≥60Vdc,Fault, Buzzer alarm | ||||||||
Safety & Working Environment | |||||||||
Safety Certification | CE(EN60950) | ||||||||
EMI Classification | EN62040-2, CLASS A | ||||||||
Operating Temperature Range | 0℃ to 45℃ | ||||||||
Storage temperature | –15℃ to 60℃ | ||||||||
Altitude | 0 - 1500 Meters | ||||||||
Relative humidity | 5% to 95% non-condensing | ||||||||
Audible noise | 60dB max | ||||||||
Cooling | Forced air , variable speed fan | ||||||||
Dimension | 350*110*407 | 350*110*407 | |||||||
Weight | 8KG | 9KG |
APPLICATION OF OUR PRODUCT |
1. Living house and home building
2. Office building, factory and warehouse
3. Shopping mall, stadium and so on
4. Power station, field operation and some huge engineer construction
5. suitable for various home appliance, Office equipment,Journeys, Camping, Tents, Boat Trip
COMPANY SHOW |
Introduction of Company
Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.
Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.
WHY CHOOSE US ? |
1, QC Control
The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.
2, Best Partner
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.
FAQ |
1. How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power
.......................................................................................................................................................................
2. How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the
size of the power inverter.
Notice:
Resistive load: you can choose the same power as the load.
Capacitive loads: according to the load, you can choose 2-5 times power.
Inductive loads: according to the load, you can choose 4-7 times power.
.......................................................................................................................................................................
3. How connection between batteries and an power inverter?
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions
.......................................................................................................................................................................
4. How to calculate the load of working hours requires configuration of the battery size?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)
.......................................................................................................................................................................
Enter Your Message