3 Phase 20KVA / 14KW, 15KVA /10.5KW True online double conversion High Frequency UPS
Contact Person : Ella
Phone Number : 0755-81495850
WhatsApp : +8613682556888
Minimum Order Quantity : | USD10000 | Packaging Details : | Standard Exported Cartons and Pallets |
---|---|---|---|
Delivery Time : | Within 15-30days after receiving your 30% TT deposit | Payment Terms : | 30% TT in advance, the balance before shipping |
Supply Ability : | 10000PCS/Month for Inverter and line Interactive UPS; Advance 3000PCS/Month for Online UPS |
Place of Origin: | China | Brand Name: | SOROTEC |
---|---|---|---|
Certification: | CE,ROHS,ISO9000 | Model Number: | HP9115C HP9315C Series 1 - 20KVA |
Detail Information |
|||
Norminal Voltage: | 220/230/240VAC Single Phase 2 Wire+G | Norminal Frequency: | 50/60 Hz |
---|---|---|---|
Frequency Range: | 50HZ:(46~54HZ);60HZ;(56HZ~64HZ) | Voltage Precision: | 220/230/240X (1±2%)VAC |
Frequency Precision: | 50/60Hz ±0.05Hz | Power Factor: | 0.9 |
Current Crest Ratio: | 3:1 | Temperature: | 0~40°C |
Highlight: | ups uninterruptible power supply,pure sine wave ups |
Product Description
High Frequency Online UPS Single 1KVA to 20KVA 1Ph in / 1Ph OUT & 3Ph in / 1Ph OUT
Key Features:
1. Its cut-edge digital technology of DSP (Digital Signal Processor), can greatly improve the products performance and system reliability, and deliver a compact integration with higher power density ;
2. Output power factor up to 0.8 - applicable to the tendency of future load evolution, and deliver higher payload capacity;
3. Total power factor up to 90% can minimize the power loss of UPS and save utilization cost for user;
4. Emergency Power Off (EPO): UPS can be instantly shut off in case of any emergency;
5. Compliance with EMC requirements of IEC61000-4, provide your device a clean electric environment.
6. Active power factor correction (PFC) technology allow sthein putpower f actor approa ching to 1 ,dramatically reducing the immunity on utility grid;
7. Excellent input frequency range makes UPS suitable to different power supply devices, i.e. generator set;
8. Parallel Kit: realize the parallel extension and redundancy function, offer more flexibility and safety for user's power supply planning;
9. Compact Design, Lower Noise;
Application
This series against the key equipment, such as special communication system and computer network system,and provide more flexible and reliable power protection for equipments require strict environment of power .
Technical Specifications of Rack Mount UPS HP9115C 1-10KVA
Model | HP9115C 1-10KVA | ||||||||||
1KT | 1KT-XL | 2KT | 2KT-XL | 3KT | 3KT-XL | 6KT | 6KT-XL | 10KT | 10KT-XL | ||
Capacity | 1KVA/800 W | 2KVA/1600 W | 3KVA/2400 W | 6KVA/4800 W | 10KVA/8000 W | ||||||
Norminal voltage | 220/230/240VAC Single phase 2 wire+G | ||||||||||
Norminal frequency | 50/60 Hz | ||||||||||
Input | |||||||||||
Voltage Range | 115~300VAC | 120~275VAC | |||||||||
Frequency Range | 50HZ:(46~54HZ);60HZ;(56HZ~64HZ) | ||||||||||
Power Factor | >0.98 | 0.99 | |||||||||
Output | |||||||||||
Voltage Precision | 220/230/240X (1±2%)VAC | ||||||||||
Frequency Precision | 50/60Hz ±0.05Hz | ||||||||||
Power factor | 0.8 | 0.8/0.9(Optional) | |||||||||
Harmonic Distortion | Linear load<3% Non-linear<6% | ||||||||||
Overload Capability | load>110%for 47s; | 105%<load≤125% for60s; | |||||||||
load>150%for 25s; | 125%<load≤150% for30s; | ||||||||||
load>200%for 300ms; | load>150%for 0.5s; | ||||||||||
Current Crest Ratio | 3:1 | ||||||||||
Transfer time | 0 ms(AC mode→DC mode);(AC mode→Bypass<4ms) | ||||||||||
Battery | |||||||||||
DC Voltage | 36VDC | 72VDC | 96VDC | 192 or 240DVC | |||||||
Recharge Time | 5 hours to 90% (it means standard model which battery inside UPS) | ||||||||||
Charging current | 1A | 4A/8A(Optional) | 1A | 4A/8A(Optional) | 1A | 4A/8A(Optional) | 2A | 4A | 2A | 4A | |
Panel Display | |||||||||||
LCD | UPS status, input/output voltage and frequency,battery voltage, capacity,load temperature,history records, adjust Voltage, ECO mode | ||||||||||
Communication | |||||||||||
Communication port | Smart RS232, SNMP (Optional) , USB(Optional) | ||||||||||
Working Environment | |||||||||||
Temperature | 0~40°C | ||||||||||
Relative Humidity | 0~95% non-condensing | ||||||||||
Storage Temperature | -25°C~55°C | ||||||||||
Elevation | 1500m | ||||||||||
Noise Level | <45dB | <50dB | <50dB | ||||||||
Physical Characteristic | |||||||||||
Weight(KG) | N.W | 12 | 6.5 | 23 | 10.5 | 31.5 | 14 | 57 | 18 | 67.5 | 20 |
G.W | 14 | 8 | 25.5 | 13 | 33.5 | 16.5 | 59 | 24 | 70 | 24 | |
Dimensions: ( W x D x H ) | 145x355x220 | 190x383x318 | 190x433x318 | 248x500x616 | 248x500x460 | 248x500x616 | 248x500x460 |
PRODUCT SHOW |
APPLICATION OF OUR PRODUCT |
1. Living house and home building
2. Office building, factory and warehouse
3. Shopping mall, stadium and so on
4. Power station, field operation and some huge engineer construction
5. suitable for various home appliance, Office equipment,Journeys, Camping, Tents, Boat Trip
COMPANY SHOW |
Introduction of Company
Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.
Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.
WHY CHOOSE US ? |
1, QC Control
The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.
2, Best Partner
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.
FAQ |
1. How to choose suitable inverter?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.
For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.
Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power
.......................................................................................................................................................................
2. How do I choose the size of the inverter?
Different types of load demand for power are different. You can view the load power values to determine the
size of the power inverter.
Notice:
Resistive load: you can choose the same power as the load.
Capacitive loads: according to the load, you can choose 2-5 times power.
Inductive loads: according to the load, you can choose 4-7 times power.
.......................................................................................................................................................................
3. How connection between batteries and an power inverter?
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions
.......................................................................................................................................................................
4. How to calculate the load of working hours requires configuration of the battery size?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:
Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)
.......................................................................................................................................................................
Enter Your Message