Send Message
Contact Us

Contact Person : Ella

Phone Number : 0755-81495850

WhatsApp : +8613682556888

Free call

High Frequency online UPS, Uninterrupted Power Supply 0.9 Output 10-20KVA

Minimum Order Quantity : USD10000 Packaging Details : Standard Exported Cartons and Pallets
Delivery Time : Within 15-30days after receiving your 30% TT deposit Payment Terms : 30% TT in advance, the balance before shipping
Supply Ability : 10000PCS/Month for Inverter and line Interactive UPS; Advance 3000PCS/Month for Online UPS
Place of Origin: China Brand Name: SOROTEC
Certification: CE,ROHS,ISO9000 Model Number: HP9315C 10 - 20KVA

Detail Information

Rated Voltage: 380VAC 3phase With Ground Rated Frequency: 50/60HZ
VoltageRange: 115~300VAC FrequencyRange: 50HZ:(46~54HZ);60HZ:(56HZ~64HZ)
Power Factor: >0.98 Voltage Regulation: 208/220/230/240X(1±2%)VAC
Frequency Regulation: 50/60HZ±0.05 Hz Current Crest Ratio: 3:1
Highlight:

ups uninterruptible power supply

,

pure sine wave ups

Product Description

High Frequency online UPS, Uninterrupted Power Supply HP9115C1-20KVA 1-3K 0.8Output

 
 

 Key Features:

1.0.9 Output Factor UPS

 

2. Large blue back light LCD for detailed Real-time UPS status display.

 

3.  Advanced online pure sine wave power supply system, with bypass repair switch, It can provide a reliable, high quality AC power source to the precision equipments, can be used widely in different fields.

 

4. Widely used to computer equipments, telecommunication systems and Industrial automatic control equipments.

 

5. Truly online design, different from offline, it can adjust the input voltage, filtering, when the AC break off, the UPS will provide an uninterruptible power source from the backup batteries.

 

6. UPS will change to bypass mode when overloading or inverter fault, when overloading remove, UPS will turn to inverter mode automatically.

 

7. N+N Parallel Redundancy and Capacity expansion for 6-20K(up to three units)

 

 

Applications:

Servers, Data-center, critical network devices, Sensitive electronic equipment, Telecom…

 

 

 

Technical Specifications of Online UPS HP9115C 1-10K

Model

HP9315C 10-20KVA

10KT-XL

15KT-XL

20KT-XL

Rated Power

10KVA/9000W

15KVA/13500W

20KVA/18000W

Rated Voltage

380VAC 3phase with ground

Rated Frequency

50/60HZ

Input

VoltageRange

115~300VAC

FrequencyRange

50HZ:(46~54HZ);60HZ:(56HZ~64HZ)

Power Factor

>0.98

Output

Voltage Regulation

208/220/230/240X(1±2%)VAC

Frequency Regulation

50/60HZ±0.05 Hz

Power factor

0.9

Voltage distortion

Linear load<3%    Non-Linear load<6%

Overload

Capability

110%~150% for 30s change to bypass model, Recover after load normal

Current Crest Ratio

3:1

Transfer time

0ms(AC mode→ Battery mode)

Battery

DC Voltage

240VDC

Recharge Current

4.2A

Display

LCD

Display input/output Voltage, Frequency, Battery voltage, Battery capacity, Loading rate.

Communication

Interface

Smart RS232, SNMP(optional) , USB(optional)

Environment

Operation Temperature

0~40℃

Humidity

0~95%non-condensing

Storage Temperature

-25℃~55℃

Sea level elevation

<1500m

Noise Level(1m)

<55dB

Physical Characteristic

Weight(KG)

N.W.

47

54

54

G.W.

53

60

60

Dimension(D x W x H)mm

570X260 X717

 

 
APPLICATION OF OUR PRODUCT

 

1. Living house and home building

2. Office building, factory and warehouse

3. Shopping mall, stadium and so on

4. Power station, field operation and some huge engineer construction

5. suitable for various home appliance, Office equipment,Journeys, Camping, Tents, Boat Trip

 

 

 

COMPANY SHOW

 

Introduction of Company

Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.

Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.

 

 

 

WHY CHOOSE US ?

 

1, QC Control

The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.

2, Best Partner

We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.

 

 

FAQ

 

1. How to choose suitable inverter?

 

If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.

 

For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.

 

Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power

.......................................................................................................................................................................

 

2. How do I choose the size of the inverter?

 

Different types of load demand for power are different. You can view the load power values to determine the

size of the power inverter.

 

Notice:

 

Resistive load: you can choose the same power as the load.

 

Capacitive loads: according to the load, you can choose 2-5 times power.

 

Inductive loads: according to the load, you can choose 4-7 times power.

.......................................................................................................................................................................

3. How connection between batteries and an power inverter?

 

We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions

.......................................................................................................................................................................

 

4. How to calculate the load of working hours requires configuration of the battery size?

 

We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:

Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)

.......................................................................................................................................................................

 

You Might Be Into These
Get in touch with us

Enter Your Message

sales@soroups.com
+8613682556888
0755-81495850