Frequency Range: 50Hz/60Hz(Auto Sensing) Waveform: Pure Sine Wave
Maximum Efficiency: 98% Standby Power Consumption: 2W
Dimension,DxWxH(mm): 128x272x355 Operating Temperature: 0℃-55℃
Storage Temperature: -15℃-60℃
High Light:

solar power inverter for home

,

home power inverter

Product Description

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar

 

Product snapshot:
Capacity : 1000W – 6000W


Nominal voltage : 220/230VAC


Nominal Frequency : 50/60HZ

 

 

Key Features:
■Pure sine wave inverter


■Built-in MPPT solar charge controller


■Selectable input voltage range for home appliances and personal computers


■Selectable charging current based on applications


■Configurable AC/Solar input priority via LCD setting


■Compatible to mains voltage or generator power


■Auto restart while AC is recovering


■Overload and short circuit protection


■Smart battery charger design for optimized battery performance


■Cold start function

 

 

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar 0

 

 

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar 1

 

Operation Diagrams and Working Conditions

Charge priority setting: Solar
Utility priority setting : Utility

1) When utility and solar are presented, battery charged from solar, Charger source will be turned to utility side in case solar panel without enough energy.

 

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar 2

 

2) When solar source is not present, battery charged from utility source, load powered from utility

 

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar 3

3) When utility source is not present, battery charged from solar source,load powered from solar and battery power.

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar 4

4) When utility and solar are not present, connected load will be powered from battery.

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar 5

Charge priority setting: Solar and Utility
Utility priority setting : Utility

 When utility and solar are presented, battery charged from both solar and utility, load powered from utility.

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar 6

Charge priority setting: Utility
Utility priority setting : Utility
When utility and solar are presented, battery charged from utility, load powered from utility.

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar 7

Charge priority setting: Solar
Utility priority setting : Solar

When utility and solar are presented, battery charged from solar source, load powered from solar  and battery. If solar priority, output source turn to utility side in case solar panel without energy or battery voltage down to pre-alarm level. If sbu priority, output source turn to utility side in case of battery voltage down to pre setting level.

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar 8

Charge priority setting: Solar and Utility
Utility priority setting : Solar

 When utility and solar are presented, battery charged from both solar and utility, load powered from solar and battery. If solar priority, output source turn to utility side in case solar panel without energy or battery voltage down to pre-alarm level. If sbu priority, output source turn to utility side in case of battery voltage down to pre setting level.

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar 9

LCD Display Information:

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar 10

Charging Controls:

Wall Mounted UPS Power Inverter Overload protection with MPPT Solar 11

 

Technical Specifications:

SPS3117CY Series
Wall mounted Integrated Solar Power Inverter technical specification
Model SSP3117CY    1000VA-5000VA
Rated Power 1000VA/800W 1000VA/800W 2000VA/1600W 3000VA/2400W 3000VA/2400W 4000VA/3200W 5000VA/4000W
INPUT
Voltage 120VAC or 230VAC 230VAC
Selectable Voltage    Range 95-140VAC or    170-280VAC(For Personal Computers) 170-280VAC(For    Personal Computers)
     65-140VAC or 90-280VAC(For Home Appliances)      90-280VAC(For Home Appliances)
Frequency Range 50Hz/60Hz(Auto sensing)
OUTPUT
AC    Voltage Regulation 110/120VAC±5%(User    selectable) or 230VAC ±5% 230VAC ±5%
     (Batt.Mode)
Surge Power 2000VA 4000VA 6000VA 8000VA 10000VA
Efficiency(Peak) 90%-93% 93%
Transfer Time 10ms(For    Personal Computers)
     20ms(For Home Appliances)
Waveform Pure sine wave
BATTERY & AC    CHARGER
Battery Voltage 24VDC 48VDC 24VDC 24VDC 48VDC 48VDC
Floating Charge Voltage 27VDC 54VDC 27VDC 27VDC 54VDC 54VDC
Overcharge Protection 31VDC 62VDC 31VDC 31VDC 62VDC 60VDC
Maximum Charge Current 10A or 10A/20A* 10A or 10A/15A* 20A or 30A 20A or 30A 10A or 15A 20A or 30A
SOLAR CHARGER
Maximum PV Array Power 600W 900W 600W 600W 900W 3000W
MPPT    Range @ Operating  30VDC~66VDC 60VDC~88VDC 30VDC~66VDC 30VDC~66VDC 60VDC~88VDC 60VDC~115VDC
     Voltage
Maximum    PV Array Open  75VDC 102VDC 75VDC 75VDC 102VDC 145VDC
     Circuit Voltage
Maximum Charge Current 25A 20A 25A 25A 18A 60A
Maximum Efficiency 98%
Standby Power Consumption 2W
PHYSICAL
Dimension,DxWxH(mm) 128x272x355 140x295x540
Net Weight(kgs) 7.4 7.6 8 12.5 13.5
OPERATING    ENVIRONMENT
Humidity 5% to 95% Relative    Humidity(Non-condensing)
Operating Temperature 0℃-55℃
Storage Temperature  -15℃-60℃
Product specifications are subject to change without further notice
Inverter    Power 800W 1000W 1600W 2400W 2400W 3200W 4000W
Pmax.generated    from  25Amp,600W 20Amp,900W 25Amp,600W 25Amp,600W 20Amp,900W 60Amp,3000W 60Amp,3000W
     solar charger
Best Panel Confguration 500Wp 1000Wp 500Wp 500Wp 1500Wp 3000Wp 3000Wp
     (250Wpx2pcs)      (250Wpx4pcs)      (250Wpx2pcs)      (250Wpx2pcs)      (250Wpx6pcs)      (250Wpx12pcs)      (250Wpx12pcs)