USB Line Interactive UPS HP5115E
Contact Person : Ella
Phone Number : 0755-81495850
WhatsApp : +8613682556888
Minimum Order Quantity : | 1PCS | Price : | Price Negotiable |
---|---|---|---|
Packaging Details : | Standard Exported Cartons and Pallets | Delivery Time : | Within 15-30days after receiving your 30% TT deposit |
Payment Terms : | 30% TT in advance, the balance before shipping | Supply Ability : | 10000PCS/Month for Inverter and line Interactive UPS; Advance 3000PCS/Month for Online UPS |
Place of Origin: | China | Brand Name: | SOROTEC |
---|---|---|---|
Certification: | CE,ROHS,ISO9000 | Model Number: | MPS9335C Ⅱ |
Detail Information |
|||
Capacity: | 50-720KVA | Input Voltage: | 380V/400V/415VAC |
---|---|---|---|
Input Frequency Range: | 50/60Hz | Power Factor: | >0.99 |
THDi: | THDi<3% | Transfer Time: | <2ms |
High Light: | backup power supply,uninterruptable power supply |
Product Description
50/60hz High Frequency Online Uninterrupted Power Supply MPS9335C Ⅱ 50-720KVA
Key Features
1.Superior energy saving and environment-friendly:
Efficiency > 96% at 50%-75% rated load, and > 95% at 25% rated load; Input PF > 0.99,input THDi<3%
2. Superior capability of powering load:
Output PF is 0.9 or 1, no need of power deration with load of leading or lagging PF
3. Easy-to-install:
Top or bottom cabling, no need of input cabling cabinet.
4. Easy-to-maintain:
Full front access, UPS, failed part can be replaced shortly
5. Easy-to-modify:
The number of battery cells can be configured flexibly, so the original batteries can be used when modifying the legacy system; moreover, the battery cell can be replaced in time when it fails without interrupting the normal operation of UPS.
6.6-inch extra large LCD that can display 12 l a n g u a g e (Chinese ,English ,Russian, French ,Spanlish and so on).
7.Provide large LCD touch screen (optional)
8.Each UPS modules provide 4.5KW charge capacity. equivalent to 10 to 12A
9.On-Line Double Conversion, fully isolating the influences of power grid pollution and power failure from utility power supply and diesel generator to load
10. Advanced DSP full digital control technologies realize higher system stability, online capacity expansion and maintenance
11.Advanced distributed active parallel technology realizes parallel operation of 4 UPS units and online capacity expansion without centralized bypass cabinet
12.Digital load sharing technology features extra low cross current and extreme high system reliability in parallel operation
13.Adaptive to severe power grid environment due to extra wide input voltage and frequency ranges
14.Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety at limit conditions
15 Intelligent battery management maintains battery automatically to prolong the battery life
16. Efficient heat dissipation and effective protection under severe environment due to its independent layer-sealed ventilation channel and redundant fan design, as well as the paint-protected circuit boards and built-in dust filter
17.Applicable voltage south America
Application
Application IDC(Internet Data Center), computing center, ISP (Internet Service Provider ),Telecom,Finance bank and
securities, Tax, hospital system, industrial automation, precision equipment, etc.
Technical Specifications
Model | MPS9335C II 50-720KVA | |
Capacity | 50-720KVA | |
Main Input | ||
Input voltage | 380V/400V/415VAC | |
Input Frequency Range | 50/60Hz | |
Power Factor | >0.99 | |
THDi | THDi<3% | |
Input power soft-start function | 5-30S settable | |
Input Voltage Ranges | 228V-476V;-20% ~ 25% at Full load ; linear derating at -25% ~ -40%; can take 70% load at -40% | |
Frequency Range | 40-70Hz | |
Battery | ||
Battery Voltage | ±240VDC,12V Battery 32~44 pcs can be chose | |
Charge Voltage accuracy | ±1% | |
Bypass | ||
Bypass Input Voltage | 380/400/415VAC 3-phase 4-wire | |
Voltage Range | Default value is -20%~+15%; -40%,-30%,-10% ~ +10%,+15%,other ranges can be set via software | |
Overload Capacity | Long term at 135% rated load,150%<load<180% more than 10 min,load> 1000% 100ms | |
Ouput | ||
Inverter Output Voltage | 380/400/415VAC 3-phase 4-wire | |
Voltage Accuracy | ±0.5% (balanced load),±1% (unbalanced load) | |
THDV | THDV<1%(linear load), THDV<3%(nonlinear load) | |
Power Factor | 1.0 | |
Three Phase Angle accuracy | 120°±0.5° | |
Current Crest Ratio | 3:1 | |
Overload Capacity | 110%1h,125%10mins , 150%1mins,> 150%200ms | |
Transfer Time | <2ms | |
System | ||
Frequency | 50Hz/60Hz(Settable) | |
Mains synchronization range | ±2Hz(Default value),adjustable with step of 0.5Hz within range of+/-0.5Hz-3Hz | |
Protection Level | IP20 | |
Communication Ports | RS232.RS485,dry contact ,SNMP card,EPO,generator port | |
System efficiency | >97% at load above 50%,>95%at load above 25%, | |
Operation Temperature | 0~40ºC | |
Storge Temperature | -25ºC~70ºC(without battery) | |
Humidity | 0~95%(no-condensing) | |
Noise(dB) | 55-62dB,Adjusted with load | |
Weight Dimension(WxDxH)mm | module:PM 50 | 50KVA power module :41.3KG |
module:PM60 | 60KVA power module:41.3KG | |
3 module cabinet | 600X1000X1400 | |
5 module cabinet | 600X1000X2000 | |
8 module cabinet | 1200X1000X2000 | |
12 module cabinet | 1800X1000X2000 | |
power module | 440X638X217-(50/60KVA) |
Enter Your Message