15KVA 13.5 KW double conversion ups , AC - DC - AC online high frequency ups

Minimum Order Quantity : 1pcs Price : 10000USD
Packaging Details : Standard Exported Cartons and Pallets Delivery Time : Within 15-30days after receiving your 30% TT deposit
Payment Terms : L/C, T/T, Western Union Supply Ability : 5000PCS Per Month
Place of Origin: China Brand Name: SOROTEC /OEM
Certification: CE,ROHS,RSO9000 Model Number: HP9335C PLUS 10-30KVA

Detail Information

Product: High Frequency Online UPS UPS Power: 15KVA
Take Loads: 13.5KW Model: Long-run Model
Transfer Time: 0ms Double Conversion: Ac-dc-ac
Parallel Working: Yes Phase: 3 Phase With Neutral
Application: Industry Service: OEM/ODM
Dimension,D*W*H: 609*250*768mm Optional SNMP: Yes
High Light:

ups uninterruptible power supply

,

high frequency ups

Product Description

 

15KVA 13.5 KW double conversion ups , AC - DC - AC online high frequency ups

 

Key Features:

 

1.True double online conversion

2.ECO mode operation for energy saving

3.DSP technology guarantees high performance

4.Output power factor 0.9

5.Wide input voltage range (110-300 VAC)

6.Active power factor correction in all phases

7.50Hz/60Hz frequency converter mode

8.Accepts dual-mains inputs

9.Emergency power off function (EPO)

10.Generator compatible

11.SNMP+USB+RS-232 multiple communications

12.3-stage extendable charging design for optimized battery performance

13.Adjustable battery numbers

14.Maintenance bypass available

15.Optional N+X parallel redundancy

16.Optional isolation transformer offers full isolation and complete common mode noise rejection

 

 

Technical Parameter:

MODEL HP9335C Plus 10-30KVA
10K 10K-XL 15K 15K-XL 20K 20K-XL 30K 30K-XL
CAPACITY 10KVA / 9KW 15KVA / 13.5KW 20KVA / 18KW 30KVA / 27KW
PHASE 3 Phase with Neutral
INPUT
Voltage Range Low Line Loss 110 VAC(Ph-N) ± 3 % at 50% Load ; 176 VAC(Ph-N) ± 3 % at 100% Load
Low Line Comeback Low Line Loss Voltage + 10V
High Line Loss 300 VAC(Ph-N) ± 3 %
High Line Comeback High Line Loss Voltage - 10V
Phase Three phase with ground
Power Factor ≥ 0.99 at 100% Load
OUTPUT
Output voltage 208/220/230/240VAC(Ph-N)
AC Voltage Regulation ± 1%
Frequency Range (Synchronized Range) 46Hz ~ 54 Hz @ 50Hz system ; 56Hz ~ 64 Hz @ 60Hz system
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Overload AC mode 100%~110%: 10min ; 110%~130%: 1min ; >130% : 1sec
Battery mode 100%~110%: 30sec ; 110%~130%: 10sec ; >130% : 1sec
Current Crest Ratio 3:1 max
Harmonic Distortion ≦ 2 % @ 100% Linear Load; ≦ 5 % @ 100% Non-linear Load
Transfer Time Line←→Battery 0 ms
Inverte←→Bypass 0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass)
Line←→ECO <10 ms
EFFICIENCY
AC mode > 89% > 89% > 89% > 90%
Battery Mode > 86% > 88% > 87% > 89%
BATTERY
Standard Model Type






 
12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah 12 V / 9 Ah
Numbers 20(18-20 adjustable) 2 x 20(18-20 adjustable) 2 x 20(18-20 adjustable) 3 x 20(18-20 adjustable)
Recharge Time 9 hours recover to 90% capacity
Charging Current 1.0 A ± 10% (max.) 2.0 A ± 10% (max.) 2.0 A ± 10% (max.) 4.0 A ± 10% (max.)
Charging Voltage 273 VDC ± 1%
Long-run Model Type Depending on applications
Numbers 18-20
Charging Current 4.0 A ± 10% (max.) 4.0 A ± 10% (max.) 4.0 A ± 10% (max.) 12.0 A ± 10% (max.)
Charging Voltage 273 VDC ± 1%
PHYSICAL
Standard Model Dimension,DxWxH(mm) 832 X250X894 832 X250X1275
Long-run Model Dimension,DxWxH(mm) 609 X250X768 832 X250X828
ENVIRONMENT
Operation Temperature 0 ~ 40°C (the battery life will down when > 25°C)
Operation Humidity <95 % and non-condensing
Operation Altitude <1000m
Acoustic Noise Level Less than 58dB @ 1 Meter Less than 60dB @ 1 Meter
MANAGEMENT
Smart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC
USB Power management from SNMP manager and web browser